Model 6100 Fire System

With sufficient power to test larger enclosures, the Model 6100 is an excellent starting point for professionals. It also offers a seamless upgrade path to the full-feature 6210F model, which allows for lower leak measurement—often essential for passing stringent enclosure integrity requirements.

This system supports hold time testing in flooded volumes up to 51,000 cubic feet (1,450 m³) for Inert agents and up to 106,000 cubic feet (3,000 m³) for halocarbon chemical agents. Equipped with the newly released, industry-changing DM32X gauge, the Model 6100 ensures precise, real-time data collection and analysis.

Why Choose Retrotec for Enclosure Integrity Testing?

Retrotec pioneered the concept of Enclosure Integrity testing in 1984 and has remained the industry leader ever since. By promoting it within NFPA and authoring the first Enclosure Integrity standard in 1986, Retrotec set the foundation for modern testing methods. As the leading researcher in enclosure testing, Retrotec provides unparalleled expertise, with every major clean agent system manufacturer worldwide relying on its technology for hold time and peak pressure predictions. All Retrotec systems come with expert technical support, ensuring professionals have the guidance they need for accurate and efficient testing.

1 x 6000 Series Fan Set

  • 6000 Series Calibrated Fan
    (120V/60Hz, 240V/50Hz, or 110V/50Hz)
  • High Power Drive
    (120V/60Hz, 240V/50Hz, or 110V/50Hz)
  • Range Ring A
  • B8 Plate
  • 8 x Blank Range Plugs
  • Blower Door Tubing Kit
  • Tubing Umbilical
  • Fan Cover
  • Power Cord
  • System Calibration Verification Report

1 x Large SmartCloth™ Door Panel & Frame

  • Large SmartCloth™ Wind Dampening Cloth Door
  • Large Aluminum Frame, Etched with Sizing Markings
  • Traveling Case

1 x DM32X Gauge Package

  • DM32X Gauge
  • Gauge Case
  • USB-C Charging Cable
  • Cat5 Cable
  • ISO17025 calibration of DM32X
  • Gauge Calibration Verification Report

1 x System Accessories Case

1 x Fan Case

4 x Roll of Grill Masks

Model 6000 Fan
Flow Into: CFM Litres/sec M3/h
Max Flow, per fan (60 Hz)

Reduces values by 15% for 50Hz fan

Free Air 8,100 3,823 13,762
50 Pa 7,700 3,634 13,082
75 Pa 7,400 3,492 12,573
Minimum Flow:  
on Included Range B1 50 Pa 95 49 161
on Optional Range 74 50 Pa 37 17 63
on Optional Range 47 50 Pa 21 10 35
on Optional Range 29 50 Pa 9 4 15
Dimensions: 22″ (55.9 cm) inlet diameter, 9.75″ (24.8 cm) long, 25″ (63.5 cm) height
Weight: 33.5 lb (15.2 kg) or 35.2 lb (16.0 kg) with Ring A & Plated B8 installed
Flow Accuracy: +/-5%
Power: 120V@60hz/22.0A or 240V@50hz/10.9A or 110V@50Hz/22.0A
Recommended Fan Calibration Interval: 5 years
Digital Gauge Model: DM32X (Click Here)
5000 Fan Max Flows
5,700 CFM50 · 2,680 l/s · 9,692 M3/h
6000 Fan Max Flows
7,700 CFM50 · 3,634 l/s · 13,087 M3/h
7000 Fan Max Flows (Battery)
8,896 CFM CFM50 · 4,198 l/s · 15,110 M3/h

Request a Quote